Osaw Industrial Products Pvt. Ltd.
Osaw Industrial Products Pvt. Ltd.
Ambala, Haryana
GST No. 06AAACO2804K2ZM
TrustSEAL Verified
Call 08048027349 42% Response Rate
SEND EMAIL

New Items

Law of Resistance Board SA022

Law of Resistance Board SA022
  • Law of Resistance Board SA022
Ask For Price
Product Price :Get Latest Price

Product Details:

ColorBlack
Packaging TypeBox
Usage/ApplicationLab
Voltage1.5-12V AC/DC
ModelSA022

Experiments :
  • Exp-1 Resistance in series combination.
  • Exp-2 Resistance in parallel combination.
  • Exp-3 Study electrical resistance phenomena in metal.
  • EXP-4 Verifying ohm’s law.
  • EXP-5 Effects of length, cross section & material on a conductor’s electrical resistance..
  • PHYSICS, Class XII, Part-1, Chapter - 3, Current electricity.
  • SCIENCE, Class X, Chapter - 12, Electricity.

Special Features :
  • Insulating blocks present on the base prevent the wires from contacting the metal base during experiment.
  • Demonstrate the characteristics of electrical resistance in metal wires.
  • All The wires have the same length and dia , but are made of different materials.
  • Multipurpose power supply.

Scope of Supply:

Cat. No.Item NameQty.
C8625Resistance board1
1m, constantan wires 24 SWG1
1m, constantan wires 30 SWG1
1m,iron wires 30 SWG1
1m,copper wires 30 SWG1
SE067Multimeter2
SN200Connecting Lead black 50cm2
SN201Connecting Lead black 100cm1
SN203Connecting Lead red 50cm2
SN204Connecting Lead red 100cm1
SV050Power supply 1.5-12V AC/DC1
Instruction manual1
Request
Callback
Products & Services

DIODE LASER KIT

DIODE LASER KIT
  • DIODE LASER KIT
Ask For Price
Product Price :Get Latest Price
The kit has been designed to perform a lot of experiment related to the light experiments to find out the wavelength of the light, width of the narrow slit or any type of pattern. 

Exp-1 To demonstrate Young’s fringes. Exp-2 To demonstrate diffraction pattern by pinhole, single slit, double slit & grating. Exp-3 To demonstrate Fresnel’s diffraction. Exp-4 To determine the slit or pinhole width. Exp-5 Light spreads when passed through a narrow aperture. Exp-6 To measure wavelength using a millimeter scale as a grating
Request
Callback
Products & Services

SPECTROMETER STUDENT-SL273

SPECTROMETER STUDENT-SL273
  • SPECTROMETER STUDENT-SL273
Ask For Price
Product Price :Get Latest Price
It is used for quantitative light experiments. The collimator is fixed on the base and the telescope can be rotated. Concealed helical focusing is provided on the telescope and collimator tubes. The collimator slit has spring loaded jaws. The graduated prism table has a vernier attached which is fixed on the telescope arm. The prism table is adjustable with the help of 3 knurled screws and it has screwed holes for attaching prism & grating holder.
Request
Callback
Products & Services

LINEAR AIR TRACK WITH DIGITAL TIMING-PRO LIGHT GATE SK099

LINEAR AIR TRACK WITH DIGITAL TIMING-PRO LIGHT GATE SK099
  • LINEAR AIR TRACK WITH DIGITAL TIMING-PRO LIGHT GATE SK099
Ask For Price
Product Price :Get Latest Price
Experiments:Exp-1 To study the linear motion under virtually frictionlessconditions.Exp-2 To study the elastic and inelastic collision.Exp-3 To study the concept of velocity.Exp-4 To study the concept of accelerations.Exp-5 To study the conservation of momentum & energy.Exp-6 To study the dependency of mass ratio to kinetic energy.

Key Features:4Accessories simply plug into the ends & top of vehicle.4Facilitates the study of mechanics.4Linear motion under frictionless condition.4Light gate with sensitivity-adjustment knob.4Precise and accurate data.4Many other experiments can also be performed with the samewireless light gates with built-in-timer.4Data can be collected on PC, tablets or smartphones.


Key Topics:4Linear motion.4Newton law of motion.4Elastic collision.4Inelastic collision.4Conservation of momentum.4Conservation of energy.4Mass ratio.
Request
Callback
Products & Services

ZEEMAN EFFECT SK075

ZEEMAN EFFECT SK075
  • ZEEMAN EFFECT SK075
Ask For Price
Product Price :Get Latest Price

Product Details:

Country of OriginMade in India
Electro MagnetFerromagnetic core
Coils500 T
Mirror opticsYes
Deal InNew Only
CMOS Camera1.3 MP, USB Interface.

Learning Objectives/experiments< To observe the Zeeman splitting of the green (546.1nm)mercury line using Fabry-Perot etalon for normaltransverse and longitudinal configuration.< Determining the polarization state of the triplet componentsin transverse configuration.< Determining the polarization state of the doubletcomponents in longitudinal configuration.



Feature1. Heavy, rigid and stable Optical bench (made of Al extrusion)2. Saddle can hold rod from 8 to 15mm.3. Height and level adjustment screws (made of SS)4. Compact electromagnet can be used in transverse/longitudinal mode.5. High resolution Fabri-Perot etalon to detect wavelengthchange of 0.002nm.6. Interference filter is 546.1nm.7. High current supply with safety sockets and dualtemperature control fan.8. Clear orbital splitting is observed on CMOS camera.

Technical dataElectro magnet : Ferromagnetic core, Coils 500 T,Current 5A (Max.), 4mm safety socket,U Core 150 x 130mm(LxH), 40 x 40mm,cross section, I Core L=150mm,Fabry Perot Etalon : Mirror optics Lamda/20, Mirror gap 3mm, Filter 532nm, Green InterferenceFilter, Clear view 40mm dia, Rod 10 mmdia.
CMOS Camera : 1.3 MP, USB Interface.Power Supply : 0-40V DC, 0-10A, voltage resolution0.1V, display 31⁄2 digit LED, currentresolution 0.1 A, primary fuse 8 Amp.Optical bench : Al exclusion, L = 1.5 mtr. with Scale,Triangular shape with end stop, 4 pointlevelling (steel screw).
Optics holder : Al, Dia. 130 x 3mm (Ø x T), H 230mmTransversal slider : 25 - 0 - 25mm, LC 0.01mm
Request
Callback
Products & Services

PLASMAGLOBES (PLS-100)

PLASMAGLOBES (PLS-100)
  • PLASMAGLOBES (PLS-100)
Ask For Price
Product Price :Get Latest Price
The small Tesla Coil produces an alternating high voltage potential which attracts or repels free electrons. When the electrons collide with the gaseous atoms and molecules inside the globe, the gas particles are ionized creating even more electrons, as well as, positive ions. A plasma is formed. When electrons return to the ionized gas, light is produced. Touching the globe with your finger provides a ground, an addition source or sink of electrons. You can also observe super, neat, wow effects by moving a fluorescent tube or neon light near the plasma globe. They will light up in your hands! 
Request
Callback
Products & Services

COMPACT RIPPLE TANK (ECONOMY) SA706

COMPACT RIPPLE TANK (ECONOMY) SA706
  • COMPACT RIPPLE TANK (ECONOMY) SA706
Ask For Price
Product Price :Get Latest Price
Key Features:4 Micro-controller based digital control.4 Compact and completely self-contained unit with features todigitally set frequencies and control amplitudes of Vibrator andLED strobe.4 Frequency 1-250Hz operation (controllable in 1 Hz step).4 LED illumination in two ways: Synchronous and IndependentMode.4 Individual digital LED display for wave and strobe frequencywith membrane keypad for control.4 13 accessories neatly packed in integrated accessory box.4 Camera mode for classroom projection.4 To study all the wave phenomena: Reflection, Refraction,Interference and Diffraction.4 Hand book with 15 experiments available.4 Experiment can be performed within minutes.

Cat. No. Item Name Qty.SA705 Ripple tank base unit 1CD1093 Tank 1Power adaptor 1C11725 Single point dipper 1C11728 Double point dipper 1C11730 Plane wave bar dipper 1CD691 Curved reflector 1C11722 Diffraction barrier 2C11718 Rectangular block shape 1C11719 Convex lens shape 1C11720 Concave lens shape 1C11717 Triangular shape 1C11723 Small diffraction barrier 1SB289 Dropper 1C12581 Young’s double slit 1C12582 Long straight barrier 1SA730 Camera with attachment 1“A” shaped base 1
Request
Callback
Products & Services

VIBRATION GENERATOR SA009A

VIBRATION GENERATOR SA009A
  • VIBRATION GENERATOR SA009A
Ask For Price
Product Price :Get Latest Price
Key Features:4Mechanical oscillations.4Max peak to peak displacement .4Total frequency range: 1 Hz to 10 kHz.4Coil and magnet assembly are enclosed.4Armature allows attachment of the item to be vibrated.

Experiments:Exp-1 To demonstrate the Kinetic Theory.Exp-2 Longitudinal and transverse waves.Exp-3 Resonance with a non constant wave length.Exp-4 To demonstrate resonance of metal strips.Exp-5 To demonstrate interference & doppler effect.Exp-6 To demonstrate reflection, refraction & diffraction.
Request
Callback
Products & Services

Ask For Price
Product Price :Get Latest Price
Features1. Built-in DC variable power supply, range 0-500V.2. Compact design less space in laboratory.3. Quick and Ready to use apparatus4. Free image capturing software.5. Apparatus with 3 leveling screws and spirit level.6. Quick and easy maintenance.
Technical dataMillikan oil drop : AC 220V, 50Hz, 5W, Plate voltage0~500V DC, Change over switchBetween +ve, -ve and 0 field, Platedistance 5±0.2mm,Total Magnification30X, Linear field of vision ≥3mm, Scaledivision 2 ± 0.01mm
USB camera : Sensor 1.3 MP, Eyepiece 10X,
Connectivity USB
Digital stop watch : Display 6 Digit, Accuracy 0.01sec,
Digit size 5mm
Scope of delivery4 1 Millikan's apparatus4 1 Digital stop watch4 1 Oil atomizer4 1 USB camera - SK198
Learning Objectives/experiments< To observe brownian movement in charged oil droplets.< To determine the quantum nature of charge.
Request
Callback
Products & Services

COMPLETE EXPERIMENTAL SYSTEM FOR POLARIZED LIGHT SN1092

COMPLETE EXPERIMENTAL SYSTEM FOR POLARIZED LIGHT SN1092
  • COMPLETE EXPERIMENTAL SYSTEM FOR POLARIZED LIGHT SN1092
Ask For Price
Product Price :Get Latest Price
Features1. Ideal for demo2. Observing polarization by reflection3. Measuring Brewster's angle4. Verifying Malus's law
Technical dataOptical Rail : Duralumin, 1 mPolarizer : Φ 20 mm with holderλ/2 Wave Plate : Φ 10 mm, λ = 632.8 nm, quartzλ/4 Wave Plate : Φ 10 mm, λ = 632.8 nm, quartzLens : f '= 150 mmBeam Expander : f '= 4.5 mmHe-Ne Laser : >1.0 mW @632.8 nmScope of delivery4 1 Optical Rail4 3 General Carrier4 1 X-adjustable Carrier4 1 X-Z adjustable Carrier4 1 Alignment Screen4 2 Lens Holder4 1 Plate Holder4 1 Adaptor Piece4 1 Optical Goniometer4 3 Polarizer Holder4 2 Polarizer4 1 λ/2 Wave Plate4 1 λ/4 Wave Plate4 1 Lens4 1 Black Glass Sheet4 1 Beam Expander4 1 He-Ne Laser4 1 Laser Holder4 1 Optical Current Amplifier
Learning Objectives/experiments< Brewster's angle measurement of a black glass.< Verification of Malus's law.< Function study of a half-wave plate.< Function study of a quarter-wave plate: circularly andelliptically polarized lightSPECIFICATIONS
Verification of Malus’s law
imported
Key Topics4 Brewster's angle4 Malus's law.4 Half-wave plate4 Quarter-wave plate
Request
Callback
Products & Services

HOLOGRAPHY EXPERIMENT KIT SN1091

HOLOGRAPHY EXPERIMENT KIT SN1091
  • HOLOGRAPHY EXPERIMENT KIT SN1091
Ask For Price
Product Price :Get Latest Price
9999
Scope of delivery4 1 Semi conductor laser4 1 Aperture Adjustable Bar Clamp4 2 Lens Holder4 6 Two-Axis Mirror Holder4 1 Plate Holder4 11 Magnetic Base with Post Holder4 2 Beam Expander4 2 Beam Splitter4 1 Continuous Ratio Beam Splitter4 3 Plane Mirror4 2 Lens4 2 Loading table4 1 Object Screen4 1 Small object4 1 Red, Yellow, Green LED lamp4 1 Illuminator4 1 Information card4 2 Holographic Plate4 1 Time exposer4 1 Single sided rotary slitSelf prepared part list4 7 500ml fine mouth bottle4 1 1000 ml Graduated cylinder4 5 500 ml Glass beaker4 1 Isopropanol (1500 ml)4 1 Distilling water (2000 ml)4 1 Glass knife4 1 30 cm Steel ruler4 1 1000W Hot blower4 1 D19 developer powder4 10 Common glass (240 x 90 x 2 mm)4 1 HY-914 Glue
Learning Objectives/experiments< Fresnel holographic photography.< Image plane holography.< One-step rainbow holographic photography.< Two-step rainbow holographic photography.< Holographic grating fabrication.< Holographic lens fabrication.< High-density high-capacity holographic data storage.< Holographic interferometry.< Holographic reproduction.
Request
Callback
Products & Services

HE-NE LASER KIT SK027/SK038

HE-NE LASER KIT SK027/SK038
  • HE-NE LASER KIT SK027/SK038
Ask For Price
Product Price :Get Latest Price
Technical dataOptical bench : Al exclusion, L = 1m, Triangular shape withend stop, 4 point levelling (SS screw)Transversal slider : 25 - 0 - 25mm, LC 0.01mm,Screen : Acrylic(translucent) 300 x 300 x 3mmLaser : He-Ne Laser (632mm), Power 2 mW, Beamspot 2.5mm, current 4mA ~ 6mA,Dimension 300 x 62 x 82mm.
Diffraction slides SL744Slit Frame Size : 50mm x 50mm, Width=0.06mm &Separation=0.20mm (Single, Double,Three, Four, Five, & Six) Single & Doubleslit Tapered
Coarse Grating : 4 & 8 lines/mm, line/space ratio 3:1 & 6:1Diffraction grating : 80 lines / mm, 300 lines / mmCircular apertures : 1.0, 0.60, 1.40, 0.30 mm nominal dia.Hologram : 50 x 50mm Transmission typePolaroids : 50 x 50mm linearly polarizedSet of 13 Objects R5199It consists of 13 : Single slit, double slit, multiple slit 3,multiple slit 4, multiple slit 5, single taperedslit, fine grating, 4 holes, circular opaquespots. gray filter, mesh, coarse grating &grid pattern.Frame Size : 50mm x 50mmMetal scale : 15 cm
Scope of delivery4 1 He-Ne laser4 1 Optical bench triangular4 1 Screen (30 x 30 cm) with cylindrical base4 1 Set of 13 objects (Indian) SK0274 1 Diffraction slides (Imported) SK0384 1 Slit holder4 1 Measuring tape (3m)4 1 Metal scale (15 cm)4 1 -10cm concave lens4 1 -5cm concave lens4 1 +10cm convex lens4 1 +20cm convex lens4 1 Prism table4 3 Fixed slider4 1 Transversal slider4 1 Fixed slider (large width)

Learning Objectives/experiments< To demonstrate that light spreads when it passes through anarrow aperture.< To observe the diffraction patterns by holes, single slit anddouble slit, mesh, grating, grid, opaque spots.< To demonstrate Young’s fringes.< To demonstrate Fresnel’s diffraction.< To measure wavelength of light using a millimeter scale asa grating.< To demonstrate fringes of equal inclination.
Request
Callback
Products & Services

PLANCKS CONSTANT SN627

PLANCKS CONSTANT SN627
  • PLANCKS CONSTANT SN627
Ask For Price
Product Price :Get Latest Price
Features1. Compact design2. stand alone unit.3. Dual purpose (Voltage and Current) 7 segment display.4. Linear control over light intensity.5. Different wavelength filters.
Technical dataPlank constant : Tungsten-halogen bulb 12V / 35W ScaleLength 400mm, Photocell Cs VacuumPhoto tube, Dark-current < 0 . 0 0 3 μA,Display mode switch to displays current (mA) or voltage (V), Current multiplier X1,X0.1, X0.01 & X0.001, Accelerate Voltage-15V to 0V & 0 to15V, < ±2%, Power supply220V / 50Hz, Measuring error < ± 15%compared with the recognized value-34 (h=6.62619x 10 J.S)
Set of colour filter : Red 635nm, Orange 570nm, Yellow540nm, Green 500nm, Blue 460nm
Scope of delivery4 1 Planck’s constant apparatus4 Set of 5 different wavelength filter.4 1 Screw driverLearning
Request
Callback
Products & Services

GAMMA SPECTROSCOPY & COMPTON EFFECT SN1038

GAMMA SPECTROSCOPY & COMPTON EFFECT SN1038
  • GAMMA SPECTROSCOPY & COMPTON EFFECT SN1038
Ask For Price
Product Price :Get Latest Price
Learning Objectives/experiments< Detecting Gamma Radiation with a scintillation counter.< Recording and calibrating Gamma Spectrum.< Identifying & determining activity of radioactive samples.< Qualitative observation of the Compton Effect.< Energy calibration.< Detector Energy Resolution.< Pair Production and Annihilation.< Counting Statistics.< Absorption of Gamma radiation.< Multichannel scaling and Half Life.Scope of delivery
4 1 Universal Computer Spectrometer with software (UCS-30)
4 1 NaI(Tl) Scintillation detector with stand4 1 USB Cable4 2 BNC Cable (for data collection and High Volatge)4 1 Set of 8 gamma sources4 1 Set of 20 Absorbers4 1 Lead Shield for radioactive sources4 1 Lead Shield for Detector Holder4 1 Instuction Manual (CD Version)
Feature1. Complete spectroscopy system designed for nuclearscience.2. UCS-30 contains MCA (Multi-Channel Analyser) with aninternal pre-amplifier, computer controlled amplifier, highvoltage, upper and lower level discriminators, ADC, andMultichannel Scaling for half-life and decay studies3. UCS-30 is operated using a computer (PC or Mac) via a USBconnection.4. It includes Mossbauer interface and preamplifier poweroutput (±12 V) for connecting detectors with externalpreamplifiers such as proportional counters and CdZnTeprobes.5. Sodium iodide (NaI) scintillator is primarily used for detectinglow levels of gamma radiation.Technical dataUCS 30 : Input BNC connector, Output MHVconnector, High voltage 0 to +2048 volts,computer controlled in 2 volt increments,USB connection, AC Power adapter.NaI Detector : For detecting low levels of gammaradiation. Dimension 38.1 mm x 38.1 mm(diameter x thickness), NaI crystal coupledto a photomultiplier tube.
lead shield : To ship and store higher activity sources upto twenty 1′′ diameter disk sources.Exterior Dimensions 2.25” x 3.6”, InteriorDimensions 1.25” x 2.65”, Wall thickness0.5”, Weight 2.13 kg.
Sources : Sealed disk (1′′ diameter),Ba-133 1 μCi (37kBq), Cd-109 1 μCi (37 kBq), Co-57 1 μCi(37 kBq), Co-60 1 μCi (37 kBq),Cs-137 1μCi (37 kBq), Mn-54 1 μCi (37 kBq), Na-221 μCi (37 kBq), Mixed “Unknown”, Cs-137,0.5 μCi (18.5 kBq), Zn-65, 1 μCi (37 kBq)
Request
Callback
Products & Services

DIELECTRIC CONSTANT & CURIE TEMPERATURE OF BARIUM TITANATE SK205

DIELECTRIC CONSTANT & CURIE TEMPERATURE OF BARIUM TITANATE SK205
  • DIELECTRIC CONSTANT & CURIE TEMPERATURE OF BARIUM TITANATE SK205
Ask For Price
Product Price :Get Latest Price
Features1. Direct reading digital capacitance meter with LCD display.2. Class APlatinum RTD temperature sensor.3. Stackable power supply take less space in laboratory.4. Oven set and Process temperature controlled bynavigation keys on temperature controller.
Technical dataDigital Capacitance : Range 50-6000pf, Resolution 1pf,Meter LCD digital displayOven Controller : Range Ambient to 473K, Resolution 1K,Stability 0.5K, Accuracy 1K, LCD digitaldisplay, Power 150 WSensor : Platinum RTD ( Class A)Scope of delivery4 1 Capacitance meter4 1 Temperature controller4 1 Probe with RTD sensor4 1 Barium Titanate sample4 1 Aluminium foil4 1 Oven with patch cord4 2 Power cord
Learning Objectives/experiments< To determine dielectric constant (K) and Curie-weisstemperature (T )C
Request
Callback
Products & Services

PERMEABILITY AND PERMITTIVITY OF AIR SK201

PERMEABILITY AND PERMITTIVITY OF AIR SK201
  • PERMEABILITY AND PERMITTIVITY OF AIR SK201
Ask For Price
Product Price :Get Latest Price
Features1. DC Regulated power supply with safety sockets and dualtemperature controlled exhaust fan.2. High voltage supply with safety socket and smart thermalsafety switch.3. Highly sensitive balance for permeability and permittivityexperiment.4. Diode Laser with 0.8 mW power..
Technical dataCoulomb & current : Dimension 30 x 35.5cm, Levelling knobs.balance 4mm safety socket, Lever position 25.5cm,Al, straight conductor L=33.5cm,dia.=3mm, Al (U type), Straight conductorL=26.5cm, dia.=3mm, Max. current 20A, AlParallel plate 12.5cmx12.5cmx0.8mm(LxWxT) Max. current 20 Amp
Power Supply : 0-30V DC, 0-20A, Input voltage 220V, ±5%,50Hz AC, Voltage resolution 0.1V, Display21⁄2 digit LED, Current Resolution 0.1Amp,Primary fuse 8 Amp
Scope of delivery4 1 Coulomb and current balance kit4 1 Power supply 0-30V DC, 0-20A4 1 Power supply 0-600V, 10mA4 1 Weight box4 2 Cylindrical base4 1 Wooden scale (100 cm)4 1 Resistance module4 1 Flexible plug leads (50 cm), yellow4 1 Flexible plug leads (100 cm), red & black4 1 Measuring tape (3 metre)
Learning Objectives/experiments< To measure the force between current carrying conductorand determine the permeability of air.< To measure the force of attraction between chargedcapacitor plates and determine the permittivity of air.< To verify the relationship of speed of light with permeabilityand permittivity of air.
Request
Callback
Products & Services

MIRAGE - MIR100

Product Price :Get Latest Price
Exp-1 To demonstrate the phenomenon of optical illusion

PHYSICS, Class XII, Part - 2, Chapter - 9, Ray optics & optical instruments.
Request
Callback
Ask For Price
Products & Services

POLARIMETER - SH294

Product Price :Get Latest Price
It is a kind of instrument for measuring the optical rotation of optically active substances e.g. Sugar. The unit is mounted in a steel box. A 6V bulb present in the base works as a source of light. Light passes through a polarising filter and again through yellow filter to the sample tube. Rotation of the polarised light can be measured by rotatable analyser which is mounted in the top panel with a fixed 0-360° scale. The sample tube may be taken out for sample keeping purpose. Suppled with polarisers, yellow filter and sample tube
Request
Callback
Ask For Price
Products & Services

PROSCOPE HR BD-HRB

Product Price :Get Latest Price
The ProScope HR is a USB handheld digital microscope designed for use with your computer. With a high-quality CMOS sensor and universal lens mount, the ProScope HR is a powerful addition to any classroom. ProScope HR includes a software that allows you to capture still images, time lapse photography, and movies. TECHNICALSPECIFICATIONS: Image sensor: 1/4?high resolution 1.3 megapixel sensor Connection type: USB Image capture resolutions: 320×240 pixels 640×480 pixels 1280×1024 pixels Video capture resolutions: 320×240 pixels @ 30 fps 640×480 pixels @ 15 fps 1280×1024 pixels @ 3.75 fps
Request
Callback
Ask For Price
Products & Services

BH-CURVE WITH DEEP LITE SOFTWARE S1010

Product Price :Get Latest Price
Learning Objectives/experiments< To study BH-Curve.< To determine the relative permeability μ in the magnetisation rcurve and the hysteresis curve as function of magnetic fieldstrength H.

Technical dataData logger : 4 input channels, 6 PIN BT connector,resolution 12 bit ADC @ 100 ksps, AnalogI/P0-5 V, O/Pchannels 12 bit DAC, AnalogO/P± 12 V max 10 mA, Current booster 1APower connector 3 PIN, DIN, USB cable.Power Supply : 220V, 50Hz AC, output ± 12 V, 3PIN DINVoltage Sensor : ±1V, 4mm socket, 6PIN BTconnectorCurrent Sensor : ±1A, 4mm socket, 6PIN BTconnectorCoils : Coil 300 turns, Wire Cu. 19SWG,Sample : Ferromagnetic core, U-Core 150 x130mm (LxH), 40 x 40mm, I-Core 150mm(L), 40x40mm.

Features1. Auto identification of Voltage and Current sensors.2. Live data transfer and Graph plotting3. Programmable delay in data acquisition4. Free data Analysing Software5. Automatic mode of demagnetization.6. Automatically determining the relative Pearmeability ofFerromagnetic material
Request
Callback
Ask For Price
Products & Services

CURRENT AND VOLTAGE SOURCES SJ250

Product Price :Get Latest Price
Scope of delivery4 1 Circuit Board4 1 Decade Resistance Box4 2 Digital Multimeter4 6 Flexible Lead Set (50cm)4 1 Table Lamp4 1 Solar Module4 1 Switch Module

Learning Objectives/experiments< V-I characteristics of a solar cell.< I-R characteristics of a solar cell as a function of theirradiance.
Request
Callback
Ask For Price
Products & Services
X

Explore More Product



Reach Us
Satish Vij (Marketing Manager)
Osaw Industrial Products Pvt. Ltd.
Post Box No. 42, O. S. A. W. Complex, Jagadhri Road
Ambala - 133001, Haryana, India


Call Us


Send E-mailSend SMS